Torpedo heater not getting fuel. Its a sears 30,000 BTU heater.
Torpedo heater not getting fuel If the air pressure is incorrect it won't siphon the fuel up from the tank properly. Despite its powerful, high-BTU output, the ProTemp 220,000 BTU SilentDrive kerosene/diesel forced air torpedo heater is the quietest forced-air heating solution for spaces up to 5500 sq. Feb 21, 2025 · I burn 5 gallons of diesel every 3 days, keeps 1400sq/ft at 60 degrees with the heater set to medium. there has to be a restriction. Jan 7, 2025 · Amazon. com/watch?v=Sa20qEH1e0ALink above is for a torpedo heater that won't light because of lack of fuel. Thread starter crackerloco; Start date Feb 21 Reddy heater 55 not getting fuel Orangepeel; Nov 25, 2024; General and Off Topic; Replies 4 Customer: craftsman troubleshooting. I have a "green machine" brand torpedo heater. Once pulled out, replace the filter if dirty. Jan 21, 2025 · Those pictures of the passed out kids in the car says it all. I have replaced the pump rotor, plastic housing, filters, nozzle. ft. I. Lots of good tips and things to check and go through when pull Dec 1, 2021 · Torpedo Heater Not Igniting [5 Easy Solutions] Torpedo heaters must be maintained regularly to make sure they run efficiently and ignite properly. 9 cuft / 400 m3. There is no getting around the basic laws of thermodynamics. Im trying to remember which fuel burned with the least toxic exhaust. The anti-tilt sensor ensures that the heater does not operate dangerously. An obvious yet often overlooked culprit is an empty fuel tank. About Press Copyright Contact us Creators Advertise Developers Terms Privacy Policy & Safety How YouTube works Test new features NFL Sunday Ticket Press Copyright Jan 14, 2018 · Ive been tasked with fixing dads torpedo heater (Toro Porta Heat 55k BTU) and it is giving me fits. If I take the air hose off the pump and put my thumb over it I can get maximum ~5 PSI. , 80,000 BTU. /h (1. Wait two minutes before trying to. I had trouble with mine after 10 years of no service. Remove the Fuel from the Tank: Carefully drain the fuel from the tank into a clean container. If it does not work then you have some fresh fuel for a new heater. Binding pump rotor. Rotary vane pump service. When it's cold, sometimes the popping blows the flame out and the thing can't be trusted to start (it has a thermostat which is handy for unattended operation) If you have a torpedo heater that seems to start, doesn't fire then shuts off , then this is the video to watch! In this video I will show you how to diagnos Feb 24, 2005 · Dayton torpedo heater not getting fuel. 4 Pivot cover outward from bottom. No Ignition or Weak Flame. If I drape a shop towel over the air intake at the rear, it seems to burn more regularly. Hose and Regulator (4. If you are using #2 heating oil or diesel fuel, those fuels are heavier and subject to jelling. Sep 26, 2019 · Low air pressure problems ?? This will help No commercials. Customer: Purchased a used torpedo heater -- has some kerosene in it. Apr 2, 2020 · Try covering the intake end about half way with a piece of cloth. Cleaned the nozzle and re-gapped the electrodes. Heating for Wide Workspace: This forced-air kerosene heater delivers 70,000 BTUs of heat, instantly warming up spaces like your workspace, barn, workshop, farm, or indoor areas up to 14,125. And no fuel to the water separator. The cloth slows down the air stream so the igniter has a chance to work. The amperage your heater needs can vary depending on its size. 2 Remove disposable 1 lb. Aug 20, 2003 · Dayton torpedo heater not getting fuel. May 21, 2022 · Pinnacle KTF 175K kerosene heater, fuel pressure will not adjust either way when screw turned on rear, stays 5ight around 5. I recomme Mr. Oct 24, 2020 · Workin on a torpedo heater that starts and stops after a few seconds Dec 1, 2022 · For one of five reasons, your torpedo heater might not work even with the lid on. 3. J. Many of these heaters use air pressure over a venturi to draw fuel to the nozzle from the tank. •donotoperateheaterwhereflammable liquidsorvaporsmaybepresent. Since a garage is not air tight get an old school kerosene heater. Ensure that your heater has an adequate supply of kerosene before attempting to ignite it. Dec 12, 2016 · No fuel leaking out, but air getting in a fuel line. Empty Fuel Tank. . 2 / 578) Feb 6, 2014 · If not, it may use the "glowbar" type igniter , and that may be burned out. Dec 29, 2017 · This heater is several years old and started doing this. So I ordered a new rotor and installed it new gaskets threads have Teflon tape on them but it will not spray fuel to ignite. •alwaysfilloutdoorsawayfromopen flame. I found that turning my heater up to high for a hour a week completely solved these issues. It worked but seemed like it wasn't working at 100%. See full list on airpurelife. oil pan 4. Over time, the wick can become clogged with soot and debris, reducing its efficiency. In this comprehensive blog post, we’ll delve into the common problems associated with kerosene torpedo heaters and provide step-by-step instructions on how to fix th Please check if the fuel filter is clogged. Long Running Time: The capacity of our 175000BTU space heater is 51L. Henderson. Wrong Pump Pressure. Install fuel filter and clean or replace the nozzle. Jan 27, 2025. The fuel filter is clean, I have replaced all the air and fuel lines, and cleaned the nozzle. youtube. Pilot Light Issue. Ill help you find what to look for, could be ignitor, photocell, fuel filter etc. Jun 13, 2024 · You can easily refill the fuel and get your heater to light up again. Second, check for fuel supply hoses being rotted or collapsed. This can be a critical safety element on construction sites. Jan 2, 2013 · Most likely dirty. maninblack: Posted 12/13/2016 06:05 (#5694494 - in reply to #5692824) the heater will not run!! Supa Dexta: Mar 7, 2024 · First and foremost, ensure that your torpedo heater has a sufficient fuel supply. Last year i ran kerosene in it with no issue. And burning a few ounces of diesel an hour is not going to heat up a 2 car garage. Scouring the market for the best torpedo heater is like looking for a needle in a haystack—but fear not, we’ve done the legwork. Bleed the air out of the fuel line by loosening the fuel line connection at the heater and allowing any trapped air to escape. Solid state relay not. Some of the more expensive heaters tell you to run your heater for 10-15 minutes on the highest setting when you first start up, and also for 10-15 minutes before shutting it down. Reply Oct 23, 2017 · Rotor cover installation and air compressor rebuild. Dec 31, 2020 · it wasnt burning as hot as it should so i tried this and it worked camera https://amzn. If any of the torpedo heater parts go bad, it can Apr 19, 2024 · Common Causes of Torpedo Heater Ignition Failure 1. 2. Same with the fuel nozzle. Top Picks for the Best Torpedo Heater – Kerosene, Propane, and Radiant Heater. Ignition System: Sparking the Flame Aug 11, 2022 · About Press Copyright Contact us Creators Advertise Developers Terms Privacy Policy & Safety How YouTube works Test new features NFL Sunday Ticket Press Copyright Nov 30, 2010 · This will show you how to adjust the pump pressure on your kerosene forced air heater or as they are commonly called, a torpedo heater. Started to stink and the center cone would not glow red like it used to. Fix No Spark was the issue with this Reddy Heat 55 INSTALL A GAUGE TO ALWAYS MONITOR YOUR PRESSURE0-15psi GAUGE(needs cheap adapter below): https://amzn. As a side note, I have several of these heaters. If the unit is accidentally tilted or falls over, the anti-tilt safeguard shuts off the fuel and the heater. Coolant in ATF - 2007 GM 6. Simple Kerosene Torpedo Heater Trouble Shooting, Repair & Pressure Adjustment to reduce smoke and fumes on a DESA (Reddy, Master, Remington, etc) I'll sh Jan 20, 2021 · Testing a Torpedo heater and finding the problem of why it wont run Mar 4, 2025 · Step-by-Step Guide on How to Clean Your Torpedo Heater Fuel Tank. A more frequent cause of a torpedo heater not igniting is having poor-quality fuel. Jun 3, 2002 · If I restrict the air on the back of the heater, it runs slightly better. May 23, 2024 · The absence of fuel in your torpedo heater can be attributed to a myriad of factors. torpedo heater rep Tips for quickly diagnosing forced air heater malfunctions and fast, easy repairs!Most problems come down to one or more of these factors: Old or contamina Today we work on a Dayton 3ve52d 210,000 btu kerosene heater i picked up to heat my garage in the winter, but like most things, it does not run. Feb 23, 2022 · Make sure your torpedo heater is getting the electricity it needs to operate correctly. If your heater is getting little to no air pressure registering on the pressure gauge, Mi-T-M has the solution you are looking for to get you back to business. cylinder from heater or turn OFF gas supply at remote cylinder valve, and disconnect hose from heater. 0 Gal. If it fires up then you may wanna consider mixing in some kerosene to make the diesel work better and the kerosene last longer. Wont LightSTICKERS, HOODIES, T-SHIRTS: https://teespring. Share: Dec 8, 2006 · Dayton torpedo heater not getting fuel. 5 Remove (4) four burner retaining screws and fuel line from burner assembly Jun 13, 2024 · You can easily refill the fuel and get your heater to light up again. 6L fuel per hour and can run for up to 11 hours without frequent refueling. to/3uni2SFTripod https://amzn. allowed to reset. 1. / 19 L, the heater consumes fuel at a rate of 0. I do not assume any responsibility for anything shown or mentioned on this channel. A clogged fuel filter or fuel line can act as an impenetrable barrier, preventing fuel from reaching the heater. If your heater won ‘t ignite or produces a weak flame, several factors could be at play: Empty Tank: The most obvious culprit! Check your kerosene tank and refill it if necessary. 9 For those who might not be familiar, fuel oil heaters operate by burning fuel oil •donotusegasoline,naphthaorvolatile fuels. Release from 2 top clips. If the fuel level is low, replenish it as per the manufacturer’s instructions. Contractor Series 125,000 BTU Forced Air Propane Outdoor Space Heater with 10 ft. Dec 17, 2020 · failed ignition of multi fuel heater or torpedo heater repair Please Consider Subscribing & Liking, Big Thanks! Let's fix this free reddyheater torpedo. My air pressure is close to correct. If it uses a spark plug, you should check the gap. •donotuseexternalfuelsource. The dude said he bought another one and this one had sat for about a year. In this vid I show how to fix a dewalt diesel shop heater also known as a torpedo heater that won't light . Under normal circumstances, the heater consumes 4. I think I found #1 off road diesel was cleanest with least fumes. But when it fails to ignite, look for the following reasons and fix your heater issues ASAP. Follow these steps to clean your torpedo heater fuel tank: 1. Remove the fuel filter and clean it with fresh fuel if the heater won’t start and produces smoke or odors. It is recommended to have your torpedo heater serviced by a qualified technician every 2-3 years to ensure optimal performance and safety. Real bad. So, it will shut down the heater even if nothing is wrong with the fuel supply. Its a sears 30,000 BTU heater. If your torpedo heater keeps shutting off, or your torpedo heater won't fire then you need to watch my video, How to Fix a Torpedo Heater One of the Cheapest and Easiest Fixes that you will Dec 28, 2016 · Having troubles with your torpedo heater not igniting? We have some helpful tips to get your kerosene portable heater back up and running. Dec 3, 2018 · I have a Reddy Heater R55BT torpedo heater I use in my garage on a line voltage thermostat. If fan is hard to turn, see Pump . Spark plug. com/stores/the-fox-shopTHE FOX SHOP BB Jan 31, 2015 · The fuel is drawn up by the VELOCITY of the airstream, not the pressure. Rotor, page 10 Oct 3, 2022 · Customer said the truck wasn't starting, I found no fuel getting to the injectors when cranking. F. Start the heater and at first everything is good for about five minutes. Once the heater gets warm you can remove the cloth. Cleaning your torpedo heater fuel tank is essential for maintaining its performance. Heater 210,000 btu forced air kerosene heater that doesn't work right. • NEVER refill the heaters fuel tank while heater is operating or is Oct 25, 2021 · 1. Label the container Dec 17, 2021 · If temperatures inside the torpedo heater reach a pre-set level, the overheat sensor will shut it off. Follow the guidelines of your manufacturer to do it properly. Posted 12/8/2016 07:31 (#5683973 - in reply to #5681081) Subject: RE: torpedo heaters ncia My old knipco will do that about once a year. Many homeowners encounter problems with these heaters from time to time. Not sure if you will save money either. 02. Now that you are aware of how to recognize and fix these issues, you now have essential knowledge regarding heater maintenance. Low air pressure or wrong pump pressure can be the caveat that prevents your heater from turning on. Heater. mine has a very fine screen on the suction line where it connects to the tank. com Mar 9, 2012 · I am working on a torpedo heater. Also, the primer on the lift pump was seized and impossible to push. Said he has trouble firing it up when its lie, but it does fine with fuel. restart heater. • NEVER use fuel such as gasoline, benzene, paint thinners or other oil compounds in this heater. The options im thinking are diesel #1 or #2 And, either on road or dyed off road. But check air pump air pressure first. As of now, it will run intermittently (burn 2-3 seconds, flame out and smoke for a second or two, then relight and repeat). Heater . It kicks on and then cycles back off after several seconds and gives an E1 code. In fact, heaters with SilentDrive technology are 50% quieter and 46% more energy efficient than equivalent conventional forced-air heaters. Set aside. com/ Flame-out control not reset. A Reddy Heater must have the air pump pressure set to factory specs in order to deliver the correct amount of fuel. Press flame-out control reset button. If it is real cold when you try to start the heater the fuel is harder to ignite. The reason it works when you put a rag on it is cause you are cutting airflow through the heater changing the mix ratio back to what it should be. to/3HrZdByif you want to support my Dec 12, 2023 · Works fine in my torpedo shop heater but not getting great results with my wick heaters unfortunately. May 25, 2009 · Hey guys. Don't leave it there unattended. Feb 15, 2024 · Are you experiencing issues with your kerosene torpedo heater?Don’t worry, you’re not alone. It has a white plastic top, and will need to be rotated until it slides up out of the 2 notched out slots around the housing. So I bought a torpedo heater, 135,000 btu, and brought it home. Jan 16, 2025 · Wick Cleaning: The wick is a crucial component of the kerosene torpedo heater, responsible for absorbing fuel and releasing it as vapor. The pump pressure det Apr 21, 2020 · Check for fuel problems if the motor runs, but the heater won’t ignite, or if you spot smoke or smell an odor coming from the unit. Be careful not to use oils with higher volatility such as gasoline. It produces heat and doesn't stink, but the popping is driving me nuts. Solution: Test the fuel pump by disconnecting the fuel line from the heater and turning the pump on. I can turn it all the way in and out, no change in pressure or burn. My little propane heater did little to take out the chill. 0L w Jan 10, 2010 · The small amount of gas mixed in did seem to cut way down on the straight diesel's oily/sooty/smokey nature, but the increased gas fumes & smell was not an acceptable tradeoff in my opinion. Mar 6, 2003 · If the fuel pressure is low and your getting more raw fuel than atomized fuel it will never ignite. This is what happens. Nov 29, 2016 · I have a Mr. Large tank for extended heating: with a tank capacity of 5. A common problem comes from using a torpedo heater with a long extension cord. Why will my gas heater not stay lit? If your pilot light won’t stay alight, it might be the thermocouple. A guy that works for us broke the rotor when checking the fins. Fuel Is Contaminated. Oct 1, 2024 · A faulty fuel pump can fail to deliver enough fuel to the heater, causing it to not get enough fuel to ignite or stay lit. Dec 19, 2018 · Repairing the used 115,000 BTU torpedo heater we bought. Should be around . In addition to kerosene, our Master torpedo heater is CSA-certified to run on #1 and #2 Diesel Fuel, JP8/Jet A Fuel and #1 and #2 Fuel Oil. Most torpedo heaters use a 120V 60Mz electrical service. Nov 13, 2007 · Dayton torpedo heater not getting fuel. The fuel pump is responsible for drawing fuel from the tank and delivering it to the heater. Torpedo heaters typically run on kerosene, diesel, or propane. Took off the lift pump and heater assembly, heater was ancient and probably original. This year im running diesel because its easier to get, and it doesn't want to ignite when it gets really Dec 15, 2016 · OK folks, I have had this multi fuel torpedo heater a few seasons now. Oct 27, 2024 · Preventative Measures for a Clean Fuel Tank. When I plugged it in, it would start and then in a couple of seconds, it would cough and sputter and quit with lots of smoke. The fuel filter is located just below the fuel line coming out of the fuel tank. If it's plugged or restricted it will affect fuel delivery. I can’t turn down the air. This helps to burn away the crud on your atomizer screen. (My gauge is bouncy). wheelman; Jan 31, 2023; General and Off Topic; Replies 3 Views 3K. Jun 20, 2024 · A faulty fuel pump can fail to deliver enough fuel to the heater, causing it to not get enough fuel to ignite or stay lit. It's a $20 gamble on the K1. to/2 May 23, 2024 · Torpedo Heater Not Igniting. Wires weren't even connected; they were ripped out. Dewalt Torpedo Heater has a no start and spitting fuel issue. 5 lbs. Make sure you use the right fuel for your torpedo heater. I am just getting it ready for the cold weather. The torpedo heater heat up faster, but for general purpose, the little diesel heaters are way better. Thing looks 20 years old, maybe older lol, says 150,000btu. be/fH84fl0jHiw Jul 12, 2024 · About this item . Dec 26, 2015 · I finally got tired of working on my chainsaws in a cold garage. These l ittle diesel heaters are way better than the torpedo heaters in the long run. However, you can also take preventative measures to minimize the buildup of sediment and debris in the tank: Use High-Quality Fuel: Always use clean, high-quality fuel. If you have good airflow through the nozzle, go over the fuel pickup. kerosene/diesel forced air heater, brand new, using #2 diesel, started the first time perfected, turned off after an hour to move to a new position, waited 10 minutes after placing in new position, heater will not start, fuel is still near full, unit is on level, don't know what number displayed next to on/off switch is, but is displaying 44 Mechanic's Trying to repair my old torpedo heater but it's really giving me fits!Taryl Fixes All Video: https://youtu. Verify that the fuel tank is full and properly connected to the heater. https://www. To ignite the fuel, kerosene or propane torpedo heaters may use a pilot light. Jul 27, 2004 · Torpedo heater on WVO. Runs on kerosene or diesel. It's getting spark and had fuel in the tank but won't suck the fuel up to spray it. (RISKOFFIREOREXPLOSION) • NEVER use this heater where flammable vapors may be present. Master Kerosene/Diesel Forced-Air Torpedo Heater, 2,000 sq. The Master 140K BTU Kerosene/Diesel Torpedo Forced Air Heater comes with the latest in safety technology as well as our rigorously tested cold-start system. Prepare the Work Area: Find a well-ventilated area and lay down a drop cloth to protect the surface. 9 L/h) under normal conditions, a full tank of fuel can run for up to 9-hours, eliminating the need for frequent refueling and ensuring peace of mind And since many torpedo heaters are portable, you’re not confined to one toasty corner—you can spread the warmth wherever you roam. Lets fix it! In "The Girlz 'N' The Barn", Taryl shows you what to look for when repairing a torpedo heater. Pulled three hoses and mouth blew air through the hoses from air motor to tank, and pulled hoses from nozzle at burner and did same. It has been giving me grief with low pump pressure and black smoke on startup. If you do not have correct air pressure it won't draw fuel no matter what else is going on with your heater. The cone is nice and cherry red and no fumes. 5 Gal. Either lack of fuel or too much fue Diesel/Kerosene Turbo shop heater - Dyna-Glo PRO heater repair. How To Fix It? Kerosene Torpedo Heater Not Working • NEVER use any fuel other than 1-K kerosene, #1 disel/fuel oil in this heater. I have been thinking about getting a propane fueled torpedo heater hoping it might cost less to run, plus both my kerosene units are getting kinda old. I may try a 50/50 mix of diesel and kerosene to see if that helps make more heat in them. In addition, there is a fuel gauge at the end of the tank to display the fuel level. torpedoheat. There was a large crack in the hose at the fitt Have a R35A Reddy Heater not getting any pressure to nozzle, Reddy Heater Not Getting Fuel To Spark Plug. •stopheaterbeforeaddingfuels. Not interested in keroseen . After 5 minutes or so cone darkens and lots of bad fumes. 050" give or take a bit. •donotstartheaterwhenchamberishot. Feb 13, 2025 · Here are the most common problems you might encounter with your kerosene torpedo heater: 1. I’m thinking that I must not be getting enough fuel or too much air. Jan 25, 2020 · The videos on my channel are for entertainment purposes only. 3 Remove (4) four screws that secure the rear cover to the. com: Torpedo Heater,Forced Air Diesel Kerosene Heater with Wheels, Portable Torpedo Space Heater with Thermostat Control for Outside, Jobsite, Garage, and Construction Sites,CSA certified (125000BTU) : Home & Kitchen Jun 16, 2024 · Immediately turn off the heater, disconnect it from the fuel source, and identify the source of the leak. Jun 12, 2020 · I have an old Reddy heater 55 kersone torpedo heater. The air pump, fuel, igniter, electrical connections, and control board of the heater could all be having issues. Adjustments and service tips. Due to this issue, your Kerosene Torpedo heater may ignite but its main PCB assembly shuts off the heater after a short period. jnvb wdhm wwhy cpip erpw vekt ddime yrbnd dpr ymzw ejvvfnx wgbo ofzqx dwoinvb kalf